Power AC/DC Clamp Meter with datalogging function
Model:3063/3064
|

|

|
|
1 Φ 2W, 1 Φ 3W,3 Φ 3W,3 Φ 4W
- RS-232 interface to talk with PC
- 4 digits with dual display LCD
- Amp / Voltage f requency measurement
- Dual display KW+PF , KVA+PF , V+A
- 4000 continuity point data logger , 25 point manual data logger
- True power / apparent power / power factor measurement
- True RMS. V , A , W , cap , lnd , phase indicator
- MIN / MAX measurement
- Peak hold detector
- Dual display A+Hz , V+Hz
EN61010-1
600V Installation CAT III
Pollution Degree 2
|
|

|
|
|
True Power & Apparent power measurement
|
|
Input
|
Resolution
|
Accuracy
|
Frequency range
|
Overload protection
|
|
V<130V, A<150A
|
0.01
|
+/- (2%+5)
|
45Hz - 500Hz
|
600V/1100A
|
|
V>130V, A<150A
|
|
V<130V, A>150A
|
|
V>130V, A>150A
|
0.1
|
+/- (2%+1)
|
|
|
Range
|
Resolution
|
Accuracy
|
Overload protection
|
|
1000A
|
0.1A
|
+/- (1.5%rdg + 5dgts)
|
1100A
|
|
|
Range
|
Resolution
|
Accuracy
|
Frequency range
|
Overload protection
|
|
1000A
|
0.1A
|
+/- (1.5%rdg + 5dgts)
|
45Hz - 500Hz
|
1100A
|
|
‧Crest Factor: <4 for stated accuracy
|
|
|
Range
|
Resolution
|
Accuracy
|
Input Impedance
|
Overload protection
|
|
600V
|
0.1V
|
+/- (0.5%rdg + 5dgts)
|
1M Ω
|
600V
|
|
|
Range
|
Resolution
|
Accuracy
|
Input Impedance
|
Frequency range
|
Overload rotection
|
|
600V
|
0.1V
|
+/- (0.5%rdg + 5dgts)
|
1M Ω
|
45Hz - 500Hz
|
600Vms
|
|
‧Crest Factor: <3 for stated accuracy
|
|
|
Range
|
Resolution
|
Accuracy
|
Overload protection
|
|
20A - 80A
|
0.1A
|
+/- (10%rdg + 10dgts)
|
1100A
|
|
80A - 1000A
|
+/- (6%rdg + 10dgts)
|
|
‧Peak Detect Acquisitions Time<=1ms
|
|
|
Range
|
Resolution
|
Accuracy
|
Overload protection
|
|
20V - 80V
|
0.1V
|
+/- (10%rdg + 10dgts)
|
600Vrms
|
|
80V - 600V
|
+/- (6%rdg + 10dgts)
|
|
‧Peak Detect Acquisitions Time<=1ms
|
|
|
Range
|
Continuity beeper
|
Open circuit voltage
|
Overload protection
|
|

|
<=0.050
|
<=3.2V
|
600Vrms
|
|
|
Range
|
Resolution
|
Accuracy
|
Frequency range
|
Overload protection
|
|
10K Ω
|
1 Ω
|
+/- (1%rdg + 5dgts)
|
<=3.2V
|
600Vrms
|
|
|
Range
|
Resolution
|
Overload protection
|
|

|
0.001V
|
600Vrms
|
|
|
Range
|
Resolution
|
Accuracy
|
Voltage sensitivity
|
Overload protection
|
|
1KHz
|
0.1Hz
|
+/- (0.5%rdg + 5dgts)
|
10V or 10A
|
600V / 1100A
|
|
5KHz
|
1Hz
|
|
|
Optional Accessories: TES-3064 RS-232 Interface Adaptor / Software
|
|
|
Maximum Voltage between any
terminal and earth ground
|
600Vrms
|
|
Numerical Dual Display
|
4 digit liquid crystal display (LCD) maximum reding 9999.
|
|
Bargraph display
|
40 Segments.
|
|
Battery Life
|
30hr approx. (Alkaline)
|
|
Jaw Opening Diameter
|
Cables f 46mm.
|
|
Operating Temperature and Humidity
|
0 ℃to 50 ℃ (32 ℉ to 122 ℉ ) R.H. < 80% non-condensing.
|
|
Storage Temperature and Humidity
|
-10 ℃ to 60 ℃ (14 ℉ to 140 ℉ ) R.H. < 70% non-condensing.
|
|
Dimensions
|
260mm(L) x 93mm(W) x 45mm(H)
|
|
Weight
|
Approx. 450g
|
|
Accessories
|
Carrying Case, Test leads, One 9V Battery & Instruction manual
|
|
|
Single-Phase Power Clamp Meter
Model 21/23 Power Harmonics and Leakage Tester
Model 19 Harmonics and Leakage Tester
|

|

|
|
MODEL PROVA 19, 21, 23
- True RMS value (V and A)
- Leakage Current Measurement at 10 μ A Resolution
- Harmonic Analysis (V and A) to the 99 th Order
- Better Understanding of High Frequency Harmonic Analysis (up to 5/6 KHz)
- Non-interrupted Harmonic Analysis
- Analysis of Total Harmonic Distortion (THD-F)
- Analysis of Crest Factor (C.F.)
- Fast Peak Function (33 μ s and 39 μ s)
- Programmable CT Ratio (1 to 250)
|
Model 21(50A) and 23(100A)
- W, KW, H.P.
- VA, KVA, VAR, KVAR
- PF, Phase Angle ( Φ )
- Energy (mWH, WH, KWH)
- Analysis of Standby Power Consumption
- Balanced 3 Φ Power Quality
- Balanced 3 Φ Sequence
|
|

|
|
|
Please refer to users manual for more detailed and up-to-date description of specification.
|
|
|
AC Watt (50 or 60 Hz, PF 0.5 to 1. CT = 1, Accuracy of Readings)
Model 21 (0 to 50A), Model 23 (0 to 100A)
|
|
Range
|
Resolution
|
Accuracy 21 (0 - 30A)
Accuracy 23 (0 - 60A)
|
Accuracy 21 (30 - 50A)
Accuracy 23 (60 - 100A)
|
|
0.000 – 9.999 W
|
0.001 W
|
±1% ± 0.02 W
|
±2% of VA ± 5dgts
|
|
10.00 – 99.99 W
|
0.01 W
|
±1% ± 0.2 W
|
±2% of VA ± 5dgts
|
|
100.0 – 999.9 W
|
0.1 W
|
±1% ± 0.2 W
|
±2% of VA ± 5dgts
|
|
1.000 – 9.999 KW
|
0.001 KW
|
±1% ± 0.02 KW
|
±2% of VA ± 5dgts
|
|
10.00 – 99.99 KW
|
0.01 KW
|
±1% ± 0.2 KW
|
±2% of VA ± 5dgts
|
|
100.0 – 999.9 KW
|
0.1 KW
|
±1% ± 0.2 KW
|
±2% of VA ± 5dgts
|
|
1000 – 9999 KW
|
1 KW
|
±1% ± 2 KW
|
±2% of VA ± 5dgts
|
|
|
AC Current (50 or 60 Hz, True RMS)
|
|
Range (Model 19,21)
|
Range (Model 23)
|
Resolution
|
Accuracy of Readings
|
|
0.30 – 60.00mA
|
0.30 – 60.00mA
|
0.01mA
|
±0.5% ± 5dgts
|
|
60.0 – 600.0mA
|
60.0 – 600.0mA
|
0.1mA
|
±0.5% ± 5dgts
|
|
0.030 – 3.000 A
|
0.030 – 9.999 A
|
0.001 A
|
±0.5% ± 5dgts
|
|
3.00 – 30.00 A
|
10.00 – 60.00 A
|
0.01 A
|
±0.5% ± 5dgts
|
|
30.00 – 50.00 A
|
6 0.00 – 99.99 A
|
0.01 A
|
±1.0% ± 5dgts
|
|
|
AC Voltage (50 or 60 Hz, True RMS)
|
|
Range
|
Resolution
|
Accuracy of R.
|
Range
|
Resolution
|
Accuracy of R.
|
|
3V – 250V
|
0.1 V
|
±0.5% ± 5dgts
|
250V – 600V
|
0.1 V
|
±0.5% ± 5dgts
|
|
|
Harmonics of AC Voltage in % and Magnitude (1 to 99th order)
|
|
Range
|
Resolution
|
Accuracy in %
|
Resolution
|
Accuracy in Magnitude
|
|
50V – 600V
|
0.1 %
|
±0.5%
|
0.1 V
|
±0.5% ± 0.5V
|
|
|
Harmonics of ACA in % Percentage and Magnitude (1 to 99th order)
|
|
Range (Model 19, 21)
|
Range (Model 23)
|
Res.
|
Accuracy (%)
|
Res.
|
Accuracy of R.
|
|
10.00 – 60.00mA
|
10.00 – 60.00mA
|
0.1 %
|
±0.5%
|
0.01mA
|
±0.5% ± 0.1mA
|
|
60.0 – 600.0mA
|
60.0 – 600.0mA
|
0.1 %
|
±0.5%
|
0.1mA
|
±0.5% ± 1mA
|
|
0.5 – 3.000 A
|
0.5 – 9.999 A
|
0.1 %
|
±0.5%
|
0.001 A
|
±0.5% ± 0.01 A
|
|
3.00 – 30.00 A
|
10.00 – 60.00 A
|
0.1 %
|
±0.5%
|
0.01 A
|
±0.5% ± 0.1 A
|
|
30.00 – 60.00 A
|
6 0.00 – 99.99 A
|
0.1 %
|
±1.0%
|
0.01 A
|
±1.0% ± 0.1 A
|
|
|
Power Factor and Phase Angle (PF, Φ ,Model 21 and 23)
|
|
Range (PF)
|
Resolution
|
Accuracy
|
Range (Φ)
|
Resolution
|
Accuracy
|
|
0.000 – 1.000
|
0.001
|
± 1°
|
-180° to 180° (0 ° to 360 ° )
|
0.1°
|
± 1°
|
|
|
Total Harmonic Distortion (THD-F, 1 to 99th order) Crest Factor (C.F., Accuracy of Readings)
|
|
Range
|
Resolution
|
Accuracy of R.
|
Range
|
Resolution
|
Accuracy of R.
|
|
0.0–999.9%
|
0.1%
|
± 0.5% ± 5 digits
|
1.00 – 99.99
|
0.01
|
± 5% ± 30 digits
|
|
|
Conductor Size
|
30mm (approx.)
|
|
Battery Type
|
1.5V SUM-3 x 2
|
|
Display
|
4+2+2 digits LCD
|
|
Power Consumption
|
5mA (approx.)
|
|
Auto-Power-Off
|
30 minutes
|
|
No. Of Samples/Period
|
512 (V & A), 256 (W)
|
|
LCD update rate
|
2 times / sec.
|
|
Weight
|
200g (battery included)
|
|
Operating Temperature
|
-10 ° C to 50° C
|
|
Operating Humidity
|
< 85% relative
|
|
Storage Temperature
|
-20° C to 60° C
|
|
Storage Humidity
|
< 75% relative
|
|
Dimension
|
210 (L) x 62 (W) x 35.6mm (H), 8.3" (L) x 2.5" (W) x 1.4" (H)
|
|
Accessories
|
test leads, Carrying bag x 1, Users manual x 1, Batteries 1.5V x 2
|
|
Option
|
alligator clips
|
|
Three-phase Power Clamp Meter
PROVA-6200 Graphic Power Quality Analyzer
|

|

|
- Analysis for Single Phase and Balanced 3 phase system
- True RMS Value (V and I)
- Active Power (K,KW,MW,GW)
- Apparent (VA,KVA,MVA) and Reactive Power (VAR,KVAR,MVAR)
- Power Factor (PF), Phase Angle( Φ )
- Energy (WH,KWH,KVARH,PFH)
- Programmable PT(1 to 3000)Ratios
- Display of Overlapped Voltage and Current Waveform
- Maximum Demand (MD in W,KW,MW) with programmable Period
- Harmonic Analysis (V and I) to 50th Order
- Display of 25 Harmonics in one screen
- Optical Isolated RS-232C Interface
- Smart Datalogging to save Battery
|
- Datalogging of 32,64,128 or 256 points/cycles
- Analysis of Total Harmonic Distortion (%THD-F)
- Graphic Phasor Diagram
- Capture 128 Transient Events (Time+Cycles+Faults) with Programmable Threshold(%),also can be reviewed in LCD
- 50000 Records with Programmable Interval (1 to 6000 seconds)
- Real-time Output of Waveform, Power Parameters and Harmonics at Command
- Large Dot Matrix LCD Display with Backlight
- Power for Long-term Monitoring
- Built -in Calendar Clock for Data Logging
|
|

|
|
|
AC Current (50 or 60 Hz, Auto Range, True RMS)
|
|
Range
|
Resolution
|
Accuracy of Reading
|
|
4.0 V - 1500.0 A
|
0.01 A
|
± 0.5 % ± 5 dgts
|
|
|
AC Voltage (50 or 60 Hz, Auto Range, True RMS)
|
|
Range
|
Resolution
|
Accuracy of Reading
|
|
4.0 - 600.0 V
|
0.1 V
|
± 0.5 % ± 5 dgts
|
|
|
Harmonics of AC Voltage in Percentage and Magniude(1 to 50th order)
|
|
Range
|
Resolution
|
Accuracy (in%)
|
Accuracy
(in Magnitude)
|
|
1 – 20 th
|
0.1 %
|
± 2 %
|
± 2 % ± 0.5 V
|
|
20 – 50 th
|
0.1 %
|
4 % of reading ± 2 %
|
4 % of reading ± 0.5 V
|
|
|
Harmonics of AC Current in Percentage and Magnitude (1 to 50th order)
|
|
Range
|
Resolution
|
Accuracy (in %)
|
Accuracy
(in Magnitude)
|
|
1 – 20 th
|
0.1 %
|
± 2 %
|
± 2 % of reading ± 0.4 A
|
|
20 – 50 th
|
0.1 %
|
4 % of reading ± 2 %
|
± 4 % of reading ± 0.4A
|
|
|
Range
|
Resolution
|
Accuracy (>20 V and >20 A)
|
|
0.000 - 1.000
|
0.001
|
± 0.04
|
|
|
Range
|
Resolution
|
Accuracy (>20 V and >20 A)
|
|
-180 ° to 180 ° (0 ° to 360 ° )
|
0.1 °
|
±1 °
|
|
|
Total Harmonic Distortion(%THD-F,1 to 50th order)
|
|
Range
|
Resolution
|
Accuracy (>20 V and >20 A)
|
|
0.0 - 20%
|
0.1%
|
± 2 %
|
|
20 - 100%
|
0.1%
|
± 6 % of reading ± 1 %
|
|
100 - 999.9%
|
0.1%
|
± 10 % of reading ± 1 %
|
|
|
Range
|
Resolution
|
Accuracy of Readings
|
|
1.00 - 99.99
|
0.01
|
± 5 % ± 30 digits
|
|
|
AC Watt (50 or 60 Hz, PF 0.5 to 1, CT=1)
|
|
Range
|
Resolution
|
Accuracy of Readings
(>20V and >20A)
|
|
10.0 - 999.9 W
|
0.1 W
|
± 1% ± 20 dgts
|
|
1.00 - 9.999 KW
|
0.001 KW
|
± 1% ± 20 dgts
|
|
10.00 - 99.99KW
|
0.01 KW
|
± 1% ± 20 dgts
|
|
100.0 - 999.9 KW
|
0.1 KW
|
± 1% ± 20 dgts
|
|
1000 - 9999 KW
|
1 KW
|
± 1% ± 20 dgts
|
|
|
Conductor Size
|
55mm(approx.), 64*24mm(bus bar)
|
|
Battery Type
|
Two 1.5 V SUM-3
|
|
Display
|
128*64 Dot Matrix
|
|
Power Consumption
|
10 mA (approx.)
|
|
Auto - Power - Off
|
30 minutes after power-on
|
|
Update time
|
2 times/sec. (display)
|
|
No. of Samples per Period
|
512 (voltage or current),256 (power)
|
|
Operating Temperature
|
-10 ℃ to 50 ℃
|
|
Operating Humidity
|
<85% RH
|
|
Storage temperature
|
-20 ℃ to 60 ℃
|
|
Storage Humidity
|
<75% RH
|
|
Dimension
|
210 mm (L) * 62 mm (W) * 35.6 mm (H),8.3"(L) * 2.5 "(W) * 1.4"(H)
|
|
Weight
|
Test leads *1 pair, Carrying bag*1, Users manual*1, Batteries 1.5V*2
|
|
Accessories
|
640g
|
|
Customer feedbacks:
"KKInstruments. Good Choice. We are not able to find suppliers that can fulfil our instrumentation needs until we came across KKInstruments. "
Richard Tee from Selangor
"They are friendly and professional. Give sincere advice on which product my company needs instead of finding the most profitable products to force sell to the customer. Will purchase from them again."
Lily from KL
"Just bought a Radiation Meter from KK which I was not able to get elsewhere. Good and the price is reaonable at RM250 per unit. Will look into their Infrared Thermometer."
Robert Liew from Bangi
Robert Liew from Bangi |
|
KYORITSU 2412 DIGITAL LEAKAGE CLAMP METER
KYORITSU 2413F DIGITAL LEAKAGE CLAMP METER
KYORITSU 2417 DIGITAL LEAKAGE CLAMP METER (WP)
KYORITSU 2431 DIGITAL LEAKAGE CLAMP METER
KYORITSU 2432 DIGITAL LEAKAGE CLAMP METER (HS)
KYORITSU 2433 DIGITAL LEAKAGE CLAMP (HZ SELECT) (RECOMMENDED)
KYORITSU 2433R DIGITAL LEAKAGE CLAMP (TRUE RMS)
KYORITSU 2434 DIGITAL LEAKAGE CLAMP
|
CM-03
Leakage Current Tester
|

|
- 10 m A Ultra High Resolution
- Large Conductor Diameter (30mm)
- ACA 5 Ranges (40mA, 400mA, 4A, 40A, 100A)
|
|
CM-05
AC / DC Current Probe
|

|
- Accurate and High Resolution
- 23 mm Conductor Diameter
- One Touch Zero
|
|
CM-07
TRMS AC / DC Clamp Meter
|

|
- High Resolution DC 10mA, AC 1mA
- True RMS
- Non-contact Current Frequency
Measurement
DCA 200-400A,ACA 200-400A,Hz 0-1000KHz
|
|
PROVA-11
AC / DC mA True RMS Clamp Meter
|

|
- Super High Resolution DC 1mA,
AC 0.1mA
- One Touch Zero for DCA
- True RMS
ACA 0-4000mA,ACA 0-30A
|
Range
|
Output
|
Accuracy
|
|
DCA 0-4000mA
|
1mA
|
+/- 1.5%rdg +/- 5dgts
|
|
|
DCA 0-30A
|
10mA
|
+/- 1.5%rdg +/- 3dgts
|
|
|
ACA 0-400mA
|
0.1mA
|
+/- 1.5%rdg +/- 5dgts
|
True RMS
|
|
ACA 0-4000mA
|
1mA
|
+/- 1.5%rdg +/- 8dgts
|
True RMS
|
|
ACA 0-30A
|
10mA
|
+/- 2.0%rdg +/- 5dgts
|
True RMS
|
|
DCV 0-400V
|
0.1V
|
+/- 1.0%rdg +/- 3dgts
|
|
|
ACV 0-400V
|
0.1V
|
+/- 2.0%rdg +/- 5dgts
|
True RMS
|
|
|
PROVA-15
AC / DC mA Current Probe
|

|
- High Resolution DC 1mA, AC 0.1mA
- Connect to an Oscilloscopes to observe Current Waveform
- Connect to Chart Recorder / Datalogger / DMM to Record Current Data
|
|
AC/DC mA True RMS Clamp Meter
Model: PROVA-11
 |
 |
- Super High Resolution DC 1mA, AC 0.1mA
- One Touch Zero for DCA
- True RMS
|
 |
|
|
Range
|
Output
|
Accuracy
|
|
DCA 0-4000mA
|
1mA
|
+/- 1.5%rdg +/- 5dgts
|
|
|
DCA 0-30A
|
10mA
|
+/- 1.5%rdg +/- 3dgts
|
|
|
ACA 0-400mA
|
0.1mA
|
+/- 1.5%rdg +/- 5dgts
|
True RMS
|
|
ACA 0-4000mA
|
1mA
|
+/- 1.5%rdg +/- 8dgts
|
True RMS
|
|
ACA 0-30A
|
10mA
|
+/- 2.0%rdg +/- 5dgts
|
True RMS
|
|
DCV 0-400V
|
0.1V
|
+/- 1.0%rdg +/- 3dgts
|
|
|
ACV 0-400V
|
0.1V
|
+/- 2.0%rdg +/- 5dgts
|
True RMS
|
|
Power Source:
2 X 1.5V AA UM3 Batteries
Current Consumption: 10mA
Operating Condition:
-10 o C to 50 o C at 85% max. RH
|
|
  |
|
KYORITSU 2007A DIGITAL AC CLAMP METER
KYORITSU 2017 DIGITAL AC CLAMP METER
KYORITSU 2002PA DIGITAL 2000A AC CLAMP METER
KYORITSU 2002R DIGITAL TRMS AC CLAMP METER
KYORITSU 2027 DIGITAL AC TRUE RMS CLAMP METER
KYORITSU 2031 DIGITAL CLAMP METER
KYORITSU 2412 DIGITAL LEAKAGE CLAMP METER
KYORITSU 2413F DIGITAL LEAKAGE CLAMP METER
KYORITSU 2417 DIGITAL LEAKAGE CLAMP METER (WP)
KYORITSU 2431 DIGITAL LEAKAGE CLAMP METER
KYORITSU 2432 DIGITAL LEAKAGE CLAMP METER (HS)
KYORITSU 2433 DIGITAL LEAKAGE CLAMP (HZ SELECT)
KYORITSU 2433R DIGITAL LEAKAGE CLAMP (TRUE RMS)
KYORITSU 2434 DIGITAL LEAKAGE CLAMP
KYORITSU 2003A DIGITAL AC/DC CLAMP METER
KYORITSU 2004 DIGITAL AC/DC CLAMP METER
KYORITSU 2009A DIGITAL AC/DC CLAMP METER (TRMS)
KYORITSU 2010 DIGITAL AC/DC CLAMP METER (HS)
KYORITSU 2033 DIGITAL AC/DC CLAMP METER
KYORITSU 2037 DIGITAL AC/DC CLAMP METER (TRMS)
KYORITSU 2300R FORK AC/DC METER (TRMS)
KYORITSU 2608A ANALOG CLAMP METER
KYORITSU 2805 ANALOG 600A CLAMP METER

|
|

|
Fluke 330 Series
Digital Current Clamp Meters
Models 333A, 334A, 335A, 336A, 337A
- Small body and jaws fit perfectly in your hand and into tight places
- Handy 'Display Hold' button keeps measurements on the display
- Meter controls are positioned so current measurements can be done with one hand (index finger on clamp opening lever and thumb on rotary switch)
- Large, backlit display is easy-to-see in less than ideal conditions
- In-rush current function (on most models) for measuring starting current for motors, lighting, etc.
- Auto shut-off maximizes battery life so the meter works when you need it
- Improved low current measurement accuracy from new microprocessor technology
- Five different models to meet your exact needs
- Three year warranty
|
| Model |
321 |
322 |
333a |
334a |
335a |
336a |
337a |

|
| 333A |
333A 400 AMP AC Digital Clamp Meter |
|
|
| 334A |
334A 600 A AC Digital Clamp Meter with Backlight |
|
|
| 335A |
335A 600 A True RMS AC Digital Clamp Meter with Backlight |
|
|
| 336A |
336A 600 A TRMS AC/DC Digital Clamp Meter with Backlight - Special Price! |
|
|
| 337A |
337A 1000 A TRMS AC/DC Digital Clamp Meter With Backlight |
|
Included Accessories
|
| |
- 1 - Soft carrying case
- 2 - AA alkaline batteries
- 1 - Instruction card
- 1 - Safety information sheet
- 1 - TL75 test lead Set
|
|
|
|
|
Taiwanese DC/AC Current Clamp Meter:
|
|
Version
|
Picture
|
Feature
|
|
CM-01
DC/AC Clamp Meter
|

|
- High Resolution DC/AC 10mA
- 23 mm Large Jaw Diameter
- One Touch Zero for DCA adjustment
DCA 150-200A,ACA 150-200A,DCV 0-400V,ACV 0-400V,W 0-400 W,Hz 0-1000KHz
|
|
CM-02/04
Clamp Meter/Automotive Clamp
|

|
- DC/AC 0.01A Resolution
- AC/DC 0.01A~200A
- 23mm Jaw Diameter
- One Touch Zero
- Temperature and Capacitance
- Auto Range V、 W 、Hz、 ℃ 、

- 3 3/4 Digits (4000 Counts)
- 0~9999 RPM(CM-04)
|
|
CM-03
Leakage Current Tester
|

|
- 10 m A Ultra High Resolution
- Large Conductor Diameter (30mm)
- ACA 5 Ranges (40mA, 400mA, 4A, 40A, 100A)
|
|
CM-05
AC / DC Current Probe
|

|
- Accurate and High Resolution
- 23 mm Conductor Diameter
- One Touch Zero
|
|
CM-07
TRMS AC / DC Clamp Meter
|

|
- High Resolution DC 10mA, AC 1mA
- True RMS
- Non-contact Current Frequency
Measurement
DCA 200-400A,ACA 200-400A,Hz 0-1000KHz
|
|
PROVA 11
AC / DC mA True RMS Clamp Meter
|

|
- Super High Resolution DC 1mA,
AC 0.1mA
- One Touch Zero for DCA
- True RMS
ACA 0-4000mA,ACA 0-30A
|
Range
|
Output
|
Accuracy
|
|
DCA 0-4000mA
|
1mA
|
+/- 1.5%rdg +/- 5dgts
|
|
|
DCA 0-30A
|
10mA
|
+/- 1.5%rdg +/- 3dgts
|
|
|
ACA 0-400mA
|
0.1mA
|
+/- 1.5%rdg +/- 5dgts
|
True RMS
|
|
ACA 0-4000mA
|
1mA
|
+/- 1.5%rdg +/- 8dgts
|
True RMS
|
|
ACA 0-30A
|
10mA
|
+/- 2.0%rdg +/- 5dgts
|
True RMS
|
|
DCV 0-400V
|
0.1V
|
+/- 1.0%rdg +/- 3dgts
|
|
|
ACV 0-400V
|
0.1V
|
+/- 2.0%rdg +/- 5dgts
|
True RMS
|
|
|
PROVA 15
AC / DC mA Current Probe
|

|
- High Resolution DC 1mA, AC 0.1mA
- Connect to an Oscilloscopes to observe Current Waveform
- Connect to Chart Recorder / Datalogger / DMM to Record Current Data
|
|
PROVA 2000/2003
AC / DC Clamp Meter
|

|
- DC/AC 2000A
- Cable f 55mm, Bus Bar 72mm(D) x 22mm(W)
- True RMS (2000)
- Average Sensing (2003)
- DCA One Touch Zero
- Auto Range A, V, W
- Continuity
- Max/Min/Hold
|
|
PROVA 2009
AC/DC True RMS WATT CLAMP
|

|
- AC+DC 1200KW
- DC/AC 2000A & ANALOG OUTPUT
- Cable F 55mm
- True RMS
- Temperature ( ℃ or ℉ )
- 0.1 ℃ / ℉ Resolution
|
|
TES 3010/3012
Prof. Clamp Meter
|

|
- ACA: 20A, 200A, 600A
- Continuity Buzzer
- Unit & Sign Display
|
|
TES 3040
AC 1000A Clamp Meter
|

|
- 3-3/4 Digital LCD with bar-graph
- Auto-power off with Data Hold and MAX/MIN mode
- Zero Adjustment/Relative Reading
|
|
TES 3050
AC /DC 1000A Clamp Meter
|

|
- 3-3/4 Digital LCD with bar-graph
- Auto-ranging off / Data Hold / Peak Hold / MAX/MIN mode
- Zero Adjustment/Relative Reading
|
|
TES 3074
AC 1000A Clamp Meter
|

|
- Capacitance Measurement (400μF).
- MAX / MIN / Data Hold.
- Phase Rotation Indicator.
- Pos Peak Hold & Neg Peak Hold.
- 1000A AC & 600V AC.
|
|
TES 3079
HVAC Trms Clamp Meter (1000A)
|

|
- Check current draw in motors and compressors.
- Use MAX/MIN/Recording in the temperature mode to assess efficiency.
- Test run/start capacitors.
- Confirm low voltage control signals.
- Measure flame safeguard device current draw.
|
|
TES 3082
True RMS Clamp Meter
|

|
- Auto-Ranging Frequency measurements
- Auto ZERO mode
- Data Hold mode
- PEAK Hold mode
- True RMS Reading
|
|
TES 3091R
AC Clamp Meter
|

|
- 3-1/2 Digital LCD, 2000 count.
- Pocket size.
- MAX hold / Data hold function.
|
|
TES 3092
AC / DC 700A Clamp Meter
|

|
- 3-1/2 Digital LCD, 2000 count.
- Pocket size.
- MAX hold / Data hold function.
- One touch DCA zero.
|
Power Clamp Meter
|
Version
|
Picture
|
Feature
|
|
PROVA-6600
3Phase Power Clamp
|

|
- AC/DC Auto Detection.
- Auto range. AC+DC true power, and True RMS AC Voltage and Current
- AC+DC 2000A, AC 600V, DC 800V
- Memory of 4 records.
- DCA/DCW Auto Zero when power clamp powering on.
|
|
PROVA-6601
3Phase Power Clamp
|

|
- AC+DC 2000A,600V Power Factor
- AC+DC 1200KW(1 F )
AC+DC 200KW(3 F )
- AC/DC Auto Detection
- Dual Display V+Hz,
A+V,KW+PF,KVA+KVAR
- PF( 3 F 3W , 3 F 4W 1 F 2W )
|
|
TES-3063/3064
Power AC/DC Clamp Meter with datalogging
|

|
- True power / Apparent Power / Power Factor
- RS-232 Interface to talk with PC
- Dual display KW + PF, KVA + PF, V+A
- A + Hz, V + Hz
- Datalogging Capacity (4000 Reading)
- Peak/MAX/MIN function
|
|
TES-3079K
3Phase Power Clamp
|

|
- Check current draw in motors and compressors.
- Use MAX/MIN/Recording in the temperature mode to assess efficiency.
- Test run/start capacitors.
- Confirm low voltage control signals.
- Measure flame safeguard device current draw.
- Confirm power sources.
|
|
TES-3095T
3095T TRMS KW Clamp Meter
|

|
- 3-3/4 Digital LCD, 4000 count, Autoranging.
- Trms KW, Current, Voltage measurement.
- AC Current 0.1A to 700A.
- Resistance and Continuity test.
- Data hold & MAX function.
- Pocket size.
- Auto Power off.
|
|
TES-3096
DC/AC KW CLAMP METER
|

|
- Compact Size
- Trms KW measurement
- AC/DC Current Measurement (AC 600A/DC 600A)
- 600V AC & 600V DC, Ohm/Continuity Beeper
- 600 V AC & 600 V DC. Ohm/Continuity Beeper
- One Touch DCA Zero
|
|
SPECIAL INTRODUCTION
PROVA 11 AC/DC mA True RMS Clamp Meter
|
 |
 |
- Super High Resolution DC 1mA, AC 0.1mA
- One Touch Zero for DCA
- True RMS
|
 |
|
|
Range
|
Output
|
Accuracy
|
|
DCA 0-4000mA
|
1mA
|
+/- 1.5%rdg +/- 5dgts
|
|
|
DCA 0-30A
|
10mA
|
+/- 1.5%rdg +/- 3dgts
|
|
|
ACA 0-400mA
|
0.1mA
|
+/- 1.5%rdg +/- 5dgts
|
True RMS
|
|
ACA 0-4000mA
|
1mA
|
+/- 1.5%rdg +/- 8dgts
|
True RMS
|
|
ACA 0-30A
|
10mA
|
+/- 2.0%rdg +/- 5dgts
|
True RMS
|
|
DCV 0-400V
|
0.1V
|
+/- 1.0%rdg +/- 3dgts
|
|
|
ACV 0-400V
|
0.1V
|
+/- 2.0%rdg +/- 5dgts
|
True RMS
|
|
Power Source:
2 X 1.5V AA UM3 Batteries
Current Consumption: 10mA
Operating Condition:
-10 o C to 50 o C at 85% max. RH
|
|
|
|
|
|