Search

Customer Service (9am-6pm, M-S)

KL Office:
See Map

207, Lvl 2, Blok B3, Leisure Commerce Square, Jln PJS8/9, 46150 Petaling Jaya, Selangor, MY. (Kurnia Building,Sunway)
Tel(KL) :
+60 3- 78762460, 78762463
Fax(KL):
+60 3-78762454

Office hour (KL):Mon-Fri 9am-6pm, Sat 9am-1pm


(Please call our office to make an appointment if you decide to come)

 

 

Johor Office :
See Map
Suite 3, 9th Floor, Wisma Sing Long, 9 Jln Zabedah, 83000 Batu Pahat, Johor, MY.
Tel(Johor) :
+60 7-4352540,4355540 Fax(Johor):
+60 7-4347299

Email: Sales@meter.com.my This e-mail address is being protected from spam bots, you need JavaScript enabled to view it

Office hour(Johor): Mon-Fri 9am to 6pm, Sat 9am-1pm


"How can we help you?"
Salesperson:Siti,Hui Hui ,Steven,Yusof, Syafiq


Customer Service(Overseas):
+00607-4352540 +00607-4355540


Email

(sales@meter.com.my)

Enquiry FormThis email address is being protected from spam bots, you need Javascript enabled to view it

Close on Sunday

Over 2,200 customers served! You can't be wrong for choosing KKInstruments!

 

awards & achievements

We’re No. 1 In Malaysia!

Put awards & achievements aside, we are just here to continue serving you our very best!

By Parameters

By Product

276S HD High Voltage Testers H.V. Detector PDF Print E-mail

276S HD

276S HD   High Voltage Testers
H.V. Detector  
230mm to 880mm  

276S HD   High Voltage Testers
H.V. Detector  
230mm to 880mm  

276S HD

FEATURES

 

http://www.sew.com.tw/images/d.gif Telescopic, compact, light-weight : Length : from 230mm to 880mm. Weight : Approx. 155g

http://www.sew.com.tw/images/d.gif High-voltage detectable : The equipment, whether in stretched state is available for voltage detection in high-tension circuits (3.3kV, 6.6kV and 24kV) whether the wires involved are naked or insulated.

http://www.sew.com.tw/images/d.gif Low-voltage detectable : The equipment can be used for voltage detection in low-tension circuits (80V ~ 600V) by holding the nameplate portion of the detecting head. Before-use check can easily be done by plugging in an AC 100V plug socket, without using a tester.

http://www.sew.com.tw/images/d.gif Easy to recognize indication : Intermittent lighting in red of a high intensity light-emitting diode and intermittent audible sound of an electronic buzzer are readily recongnizable at a full daylight, noisy location.

http://www.sew.com.tw/images/d.gif Waterproof : The detecting head, being tightly enclosed, is free from any trouble due to dust, dirt, water or the like.

http://www.sew.com.tw/images/d.gif Dielectric strength :

http://www.sew.com.tw/images/d.gif (a) Between Sensing tip ~ Grip portion : 50kVAC, 1 min (The detector has to be stretched).

http://www.sew.com.tw/images/d.gif (b) Between Sensing tip ~ Nameplate portion : 4kV AC, 1 min.

http://www.sew.com.tw/images/d.gif Construction : Waterproof (detecting head impervious to water).

http://www.sew.com.tw/images/d.gif Insulation resistance : Measure the insulation resistance with the high voltage insulation tester. The areas we measure are the same as dielectric strength test.

http://www.sew.com.tw/images/d.gif (a) Between Sensing tip ~ Grip portion : 1kV (The detector has to be stretched). The insulation resistance has to be more than 2000M Ohm.

http://www.sew.com.tw/images/d.gif (b) Between Sensing tip ~ Nameplate portion : 1kV. The insulation resistance has to be more than 2000M Ohm.

http://www.sew.com.tw/images/d.gif Leakage current test : Put high voltage on the parts listed below.

http://www.sew.com.tw/images/d.gif (a) Between Sensing tip ~ Grip portion : 50kV AC, 1 min (The detector has to be stretched). The leakage current has to be 100uA or less than 100uA.

http://www.sew.com.tw/images/d.gif (b) Between Sensing tip ~ Nameplate portion : 4kV AC, 1 min. The leakage current has to be 100uA or less than 100uA

http://www.sew.com.tw/images/d.gif Meets EN 61010-1, EN50081-1, EN 55082-1, EN 55022, EN 61000-4-2, EN 61000-4-3

http://www.sew.com.tw/images/d.gif This model 276 HD detects the presence of voltage in AC lines. An elongate insulation rod permits checking of high tension circuits at safe distance for voltage.

http://www.sew.com.tw/images/d.gif The equipment is compact, light weight, and easy to handle, and is also available for voltage detection in low-tension circuits.

SPECIFICATIONS

 

Working Voltage Range

H.V. : 3kV ~ 24kV AC ...... hold grip portion to detect.

 

L.V. : 80V ~ 600V AC ...... hold anmeplate portion to detect.

Frequency

50Hz / 60Hz

Operation Test (Initial voltage)

(a) When stretched, hold the grip portion. Put the sensing tip in contact with the voltage : 250V AC +/- 50V the LED and buzzer should work.

 

(b) When retracted, hold the nameplate portion. Put the sensing tip in contact with the voltage : 80V AC or below the LED and buzzer should work.

Operation start distance

Distance at which operation starts when front metal is brought near dia. 5mm O.C. wire with grip portion meld by hand.

 

Where 24kV / dia. 3mm (voltage to ground) ...... abt 20 cm.

 

Where 6.6kV / dia. 3mm (voltage to ground) ...... abt 3 cm.

 

Where 3.3kV / dia. 3mm (voltage to ground) ...... abt 1 cm.

Woking temperature rang

-10 degree C ~ +50 degree C

Battery

2 button-cells LR44 (1.5V)

 

Enquiry form

Enquiry Form
Title
Invalid Input
Purpose
Invalid Input
Contact Person (*)
Please type your full name.
Company
Invalid Input
Handphone
Invalid Input
Office Tel
Invalid Input
Office Fax
Invalid Input
E-mail (*)
Invalid email address.
Country
Invalid Input
Location




Invalid Input
Brand 1
Invalid Input
Model 1
Invalid Input
Brand 2
Invalid Input
Model 2
Invalid Input
Question
Invalid Input
Photo/File
Invalid Input
.gif .pdf .jpg .jpeg .doc .xls
You may upload any photo/file and send it to us.