| GRA002-GL820 20 multi-channel logger (up to 200ch) |
|
|
|
|
GL820
Includes Software, 100 to 240 VAC Adapter and User Manual Huge 2GB Flash Memory,
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Number of channels |
20 ch |
40 ch |
100 ch |
200 ch |
|
GL820 Unit |
1 set |
1 set |
1 set |
1 set |
|
Extension terminal base kit (B-537) |
N/A |
1 set |
1 set |
1 set |
|
20ch extension terminal set (B-538) |
N/A |
1 set |
4 sets |
9 sets |
All channels are isolated, each with multifunction input

Isolated channels, each with multifunction input
It contains an isolated input system which ensures that signals are not corrupted by inputs to other channels, thus eliminating wiring concerns. The GL820s multi-type inputs are suitable for voltage, temperature, humidity, pulse, and logic signals, enabling combined measurements of different phenomena like temperature/humidity and voltage.

Maximum sampling rate of up to 10ms
Provides faster sampling rates for voltage measurements. Can achieve 10ms sampling interval when limiting the number of channels in use.
Sampling interval |
10ms |
20ms |
50ms |
100ms |
200ms |
500ms |
1s |
2s |
|
|
Channels |
1 |
2 |
5 |
10 |
20 |
50 |
100 |
200 |
|
|
Measurement*2 |
Voltage |
X |
X |
X |
X |
X |
X |
X |
X |
|
Temp. |
N/A |
N/A |
N/A |
X |
X |
X |
X |
X |
|
X:
selection is available, N/A: selection is not available
*2:
For humidity measurements, the 0-1 V range and scaling function are used to display results directly in Relative Humidity. Sampling rate limitations are same as those for voltage measurement.
External sampling function
Captured data can be synchronized with external timing signals when the external sampling rate function is used.*3
*3:
The Logic/alarm cable, (B-513 option), is needed to connect the alarm output ports.
TOP
Huge built-in 2GB Flash memory
Built-in 2GB Flash Memory for reliable long term measurement
The 2GB Flash Memory enables secure long term data measurement without using an external storage device. Data is retained even when power is turned off because flash memory is used.
Capturing time*4 (20 Analogue channels being used.)
|
[unit: days] |
|||||||
|
Sampling interval |
10ms*5 |
50ms*5 |
100ms*5 |
200ms |
500ms |
1s |
2s |
|
Built-in 2GB Flash Memory |
29 |
72 |
89 |
101 |
253 |
506 |
5,068 |
|
512MB USB memory stick*6 |
7 |
18 |
22 |
25 |
64 |
129 |
1,294 |
*4:
The above figures are approximate.
*5:
The sampling rate is limited by the number of channels in use. (10ms: 1ch, 50ms: 5ch, 100ms: 10ch)
*6:
Standard USB memory devices without high-end functions such as fingerprint recognition are required.
Ring memory function
The most recent data is saved when internal memory or external memory is configured in ring memory mode. Captured data size in ring memory mode is limited to 1/3 of available memory.
Hot-swappable USB memory sticks
Also supports popular USB memory sticks for external storage. The GL820 saves measured data directly to USB memory sticks. USB memory sticks can be replaced during measurement without data loss.

TOP
Large easy-to-read 5.7-inch wide TFT color LCD

Utilises a bright clear 5.7-inch wide TFT color LCD monitor (VGA: 640 x 480 dots). Makes it easy to read data in waveform or digital form and to check your measurement parameter settings. The background color of the screen can be set to black or white.
![]() Waveform display (Analog + Digital) |
|
|
|
|
PC-friendly, supports USB memory stick, has USB and LAN ports
Supports USB memory devices
Captured data can be saved directly to USB memory sticks when these are chosen for external storage.

Easy connection to PC via USB or Ethernet
The GL820 can be controlled by a PC if connected by USB cable, allowing transfer of data to a PC in real-time. If you need to move large data files to your PC then the GL820 can emulate an external USB drive for quick data transfer.
The WEB & FTP server function, FTP client-server function and NTP client function are supported when the GL820 is connected to the LAN via the Ethernet port.

TOP
Easy application software
Easy connection to PC
The GL820 can be controlled by a PC if connected by USB cable, allowing transfer of data to a PC in real-time.

If you need to move large data files to your PC then the GL820 can emulate an external USB drive for quick data transfer.

Up to 10 units or 500 channels can be connected to 1 PC through LAN or USB. Measurements can be performed simultaneously or independently.

Various measurement screens
Select from 4 screens such as the Y-T (waveform + digital), Y-T (large waveform), digital view and report view to display measurements in real time.

The direct-Excel function enables captured data to be written directly to an Excel file.

Informative data replay screens
Three screens are available to view measurements in replay mode. The Y-T (waveform) display, the digital display and the X-Y graph can be selected to show your specified data. The maximum, minimum, average and peak-to-peak values between cursors are shown when using the digital display screen.

Simple configuration screens
The number of configuration screens has been reduced to five. Parameters can be set easily while viewing measured waveforms.

Useful functions
Post-process your captured data with useful functions for arithmetic calculation, statistical calculation, search and file format conversion.

The configuration of CSV file can be specified.
Other features
Alarm output function

Alarm signals can be output when alarm conditions occur. Four alarm output ports are fitted.*7
*7:
The Logic/alarm cable, (B-513 option), is needed to connect the alarm output ports.
Alarm warnings can be sent via E-mail when computer is connected to LAN.
Can be used with 3 types of power source
Chose from AC supply, DC supply or the optional battery pack which enables 6 hours*8 of continuous measurement. The power source is automatically switched to the battery pack when the AC power supply is interupted. If the capacity of the battery pack goes low then measurement is automatically terminated and the captured data file is closed and protected.
*8:
DC power drive cable and battery pack are optional extras. Measuring time by using the battery pack varies on the conditions.

GL820
![]()
GL820 Main Unit Specifications
|
item |
Description |
|
|
Number of analog input channels |
20 ch, Expandable up to 200 ch by unit of 20 ch |
|
|
External input output |
Input *1 |
Trigger or Sampling input 1ch, Logic or Pulse input 4 ch |
|
Output *1 |
Alarm output 4 ch |
|
|
Sampling interval |
10 ms to 1 h (in 10 ms to 50 ms, voltage only and limited channel), External |
|
|
Time scale |
1 sec to 24 hour/division |
|
|
Trigger function |
Action |
Start or stop capturing data by the trigger |
|
Source |
Start: Off, Input signal, Alarm, External *1, Clock, Week or Time |
|
|
Stop: Off, Input signal, Alarm, External *1, Clock, Week or Time |
||
|
Combination |
OR or AND condition at the level of signal or edge of signal |
|
|
Condition |
Analog: Rising, Falling, Window-in, Window-out |
|
|
Pulse: Rising, Falling, Window-in, Window-out |
||
|
Logic: Rising, Falling |
||
|
Alarm function |
Detecting method |
Level or edge of signal |
|
Condition |
Analog: Rising, Falling, Window-in, Window-out |
|
|
Pulse: Rising, Falling, Window-in, Window-out |
||
|
Logic: Rising, Falling |
||
|
Alarm output *1 |
4 channels, Output type: Open collector (pulled-up to 5 V by resistor 10 kΩ) |
|
|
Pulse input function *1 |
Accumulating count mode |
Accumulating the number of pulses from the start of measurement |
|
Instant count mode |
Counting the number of pulses per sampling interval |
|
|
Rotation count (RPM) mode |
Counting the number of pulses per second and then it is converted to RPM |
|
|
Max. input pulse rate |
50k pulses/sec or 50k counts per sampling interval (16 bits counter is used) |
|
|
Calculation function |
Between channels |
Addition, Subtraction, Multiplication and Division for analog input |
|
Statistical |
Select two calculations from Average, Peak, Max., Min., RMS |
|
|
Search function |
Search for analog signal levels, values of logic or pulse or alarm point in captured data |
|
|
Interface to PC |
Ethernet (10 BASE-T/100 BASE-TX), USB (Full speed) |
|
|
Storage device |
Built-in Flash memory (2 giga-bytes), USB memory device *2 |
|
|
Data saving function |
Captured data |
Direct saving of data into built-in Flash memory or USB memory device |
|
Others |
Setting conditions, Screen copy |
|
|
Ring capturing mode |
Function: ON/OFF, Number of capturing point: 1000 to 2000000 (size of the capture data will be limited to 1/3 of available memory when in Ring Mode) |
|
|
USB memory device emulation |
USB Memory emulation mode (Transfer or delete the file in built-in memory) |
|
|
Engineering scale function |
Set based on the reference point of the scaled output and input signal for each channel (Voltage measurement: four points are necessary to scale the output, Temperature measurement: two points are necessary to scale the output). |
|
|
Display |
Size |
5.7 inch TFT color LCD (VGA: 640 x 480 dots) |
|
Formats |
Waveform + Digital, Waveform only, Calculation + Digital, Expanded digital |
|
|
Operating environment |
0 °C to 45°C, 5 % to 85 % RH |
|
|
Power source |
AC adapter (100 V to 240 V, 50/60 Hz) |
|
|
Power consumption |
32VA or lower |
|
|
External dimensions (WxDxH) |
approx. 232 x 152 x 50 mm |
|
|
Weight |
approx. 900 g (Excluding AC adapter and battery pack) |
|
Software specifications
|
Item |
Description |
|
Supported OS |
Windows XP / Vista / 7 (32 bits and 64 bits edition) |
|
Functions |
Control GL820, Real-time data capture, Replay data, Data format conversion |
|
GL820 setting control |
Input settings, Memory settings, Alarm settings, Trigger settings |
|
Controlled units |
Up to 10 units or 500 channels |
|
Captured data |
Transfers data in real-time (in binary or CSV format), saved data in GL820 or the USB memory |
|
Displayed information |
Analog waveforms, Logic waveforms, Pulse waveforms, Digital values |
|
Display modes |
Y-T waveforms, Digital values, Report, X-Y graph (specified period of data, data reply only) |
|
Warning functions |
Sends E-mail to the specified address when the alarms occur |
|
File format conversions |
Converts the specified period data or all data to the CSV format (thinning function is available) |
|
Report functions |
Creates the daily or monthly report automatically (can also export directly to Excel) |
Standard accessories
|
Item |
Description |
Quantity |
|
AC adapter |
100 V to 240 V AC, 50/60 Hz (with specified type of power cord) |
1set |
|
CD-ROM |
User's manual (PDF format), Application software |
1piece |
|
Quick Start Guide |
|
1copy |
Analog input specifications
|
Item |
Description |
|||
|
Type of input terminal |
Screw terminal (M3 screw) |
|||
|
input method |
Scans by the photo-MOS-relay, all channels isolated, balanced input |
|||
|
Measurement range |
Voltage Temperature |
20, 50, 100, 200, 500 mV, 1, 2, 5, 10, 20, 50 V, and 1-5 V /F.S. |
||
|
Resistance Temperature Detectors (RTDs): Pt100, JPt100 (JIS), Pt1000 (IEC751) |
||||
|
Humidity |
0 to 100% |
|||
|
Filter |
Off, 2, 5, 10, 20, 40 (moving average in selected number) |
|||
|
Measurement accuracy *4 |
Voltage |
0.1% of F.S. |
||
|
Temperature |
Thermocouple |
Measurement range |
Measurement accuracy |
|
|
R/S |
0 °C ≦ TS ≦ 100 °C |
±5.2 °C |
||
|
B |
400 °C ≦ TS ≦ 600 °C |
±3.5 °C |
||
|
K |
-200 °C ≦ TS ≦ -100 °C |
±(0.05 % of reading +2.0 °C) |
||
|
E |
-200 °C ≦ TS ≦ -100 °C |
±(0.05 % of reading +2.0 °C) |
||
|
T |
-200 °C ≦ TS ≦ -100 °C |
±(0.1 % of reading +1.5 °C) |
||
|
J |
-200 °C ≦ TS ≦ -100 °C |
±2.7 °C |
||
|
N |
0 °C ≦ TS ≦ 1300 °C |
±(0.1 % of reading +1.0 °C) |
||
|
W |
0 °C ≦ TS ≦ 2000 °C |
±(0.1 % of reading +1.5 °C) |
||
|
|
Reference Junction Compensation (R.J.C.): ±0.5 °C |
|||
|
RTD |
Measurement range |
Measurement accuracy |
||
|
Pt100 |
-200 °C to 850 °C (FS=1050 °C) |
±1.0 °C |
||
|
JPt100 |
-200 °C to 500 °C (FS=700 °C) |
±0.8 °C |
||
|
Pt1000 |
-200 °C to 500 °C (FS=700 °C) |
±0.8 °C |
||
|
A/D Converter |
ΣΔtype, 16 bits (effective resolution: 1/40000 of measuring full range) |
|||
|
Maximum input voltage |
Between +/- terminal |
60 Vp-p |
||
|
Between channels |
60 Vp-p |
|||
|
Between channels / GND |
60 Vp-p |
|||
|
Withstand voltage |
Between channels |
350 Vp-p (1minute) |
||
|
Between channels(-) / GND |
350 Vp-p (1minute) |
|||
*1
Logic alarm cable (B-513) option is required.
Input signal of External sampling, Logic, Pulse; Maximum voltage: 24 V, Threshold: approx. 2.5 V, Hysteresis: approx. 0.5 V
*2
Size of the USB memory device is unlimited. Maximum file size is limited to 2 GB
*3
DC drive cable (B-514) or battery pack (B-517) option is required.
*4
Subject to the following conditions;
- Room Temperature is 23 °C±5 °C
- When 30 minutes or more have elapsed after power was turned on.
- Filter is set to 10
- Sampling rate is set to 1s with 20 channels.
- GND terminal is connected to ground.
GL820
![]()
Options and accessories
|
Item |
Model number |
Remarks |
|
Logic alarm cable |
B-513 |
2m long (no clip on end of cable) |
|
DC drive cable |
B-514 |
2m long (no clip on end of cable) |
|
Battery pack |
B-517 |
1piece (7.4V 2200mAh, 17Wh) |
|
Humidity sensor* |
B-530 |
3m long (with power plug) |
|
Extension terminal base kit |
B-537 |
Terminal base, cable |
|
20ch extension terminal set |
B-538 |
Terminal base, Terminal unit (20ch), fixing plate |
|
Logic alarm cable |
DC drive cable |
Battery pack |
|
Humidity sensor |
Extension terminal base kit |
20ch extension terminal set |
*
Operating environment: -25°C to 80°C